banner
Home / Products / Covid Test
Products
Fcov The Feline Coil Virus Antigen Rapid Test

Fcov The Feline Coil Virus Antigen Rapid Test

J&G Biotech Ltd (Reg. No.: 08419172) 326 Cleveland Road, London, England E18 2AN, UK
Basic Info
Model NO. JCA106C
Trademark PETX
Origin China
HS Code 3822001000
Production Capacity 50000PCS/Month
Product Description
  • INTENDED USE
  • The FCoV Antigen Rapid Test is a test cassette to detect the presence of FCoV Ag in cat's pleural fluid, ascitic fluid or feces specimen, to provide a reference for diagnosis of Feline Infectious Peritonitis (FIP) infection.
    Assay Time: 5-10 minutes
    Specimen: Pleural fluid, ascitic fluid or feces.
  • PRINCIPLE
  • The FCoV Ag Rapid Test is based on sandwich lateral flow immunochromatographic assay.
  • REAGENTS AND MATERIALS
  • Test devices
  • Disposable capillary droppers
  • Assay buffers
  • Products Manual
  • STORAGE AND STABILITY
  • The kit can be stored at room temperature (4-30°C). The test kit is stable through the expiration date (24 months) marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight.
  • TEST PROCEDURE
  • Allow all materials, including specimen and test device, recover to 15-25ºC before running the assay.
  • Take out the test device from the foil pouch and place it horizontally.
  • Collect the pleural fluid or ascitic fluid from the patient cat, do filtration and centrifuge to get rid of the impurities. Use the clear fluid in the assay. If it is pleural fluid or ascitic fluid, using a dropper to place 1 drop (approx.40μL ) of the prepared fluid specimen into the sample hole "S" of the test device. Then drop 2 drops (approx. 80μL) of the assay buffer into the sample hole immediately. NOTE: If fluid specimen is enough, place around 0.5mL of fluid specimen into the assay buffer and mix well for use directly.
  • If it is feces specimen, collecting a tip of cat's feces with the swab stick. Insert the swab into the provide assay buffer tube for dilution. Shake to make it sufficiently resolved and use the mixture in the assay.
  • Interpret the result in 15-20 minutes. Result after 20 minutes is considered as invalid.

Fcov The Feline Coil Virus Antigen Rapid Test

 

  • INTERPRETATION OF RESULTS
  • Positive (+): The presence of both "C" line and zone "T" line, no matter T line is clear or vague.
  • Negative (-): Only clear C line appear. No T line.
  • Invalid: No colored line appears in C zone. No matter if T line appears.
  • PRECAUTIONS
  • All reagents must be at room temperature before running the assay.
  • Do not remove test cassette from its pouch until immediately before use.
  • Do not use the test beyond its expiration date.
  • The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.
  • All specimens are of potential infection. It must be strictly treated according to the rules and regulations by local states.
  • LIMITATION
  • TheFCoV Antigen Rapid Test is for in vitro veterinary diagnosis use only. All result should be considered with other clinical information available with veterinarian. It is suggested to apply a further confirmative method such as RT-PCR when positive result was observed.

Fcov The Feline Coil Virus Antigen Rapid Test


J&G Biotech Ltd (Reg. No.: 08419172)
326 Cleveland Road, London, England E18 2AN, UK

Fcov The Feline Coil Virus Antigen Rapid Test

Fcov The Feline Coil Virus Antigen Rapid Test

Fcov The Feline Coil Virus Antigen Rapid Test